International Medical Lasers
in partnership with Quanta SystemLitho 100
THE REVOLUTION IN HOLMIUM SURGERY
Litho 100 Holmium laser (2.1 μm) meets the increasing demand for efficacy, flexibility and cost-effectiveness with a unique multi-application laser platform able to perform both Lithotripsy and HoLEP.
Litho 100 can reach up to 105w power and brings outstanding innovation by offering the exclusive Vapor Tunnel™, Virtual Basket™ and MasterPULSE technologies.
This device offers impressive settings with both energy and frequency (up to 80 Hz).
Features
√ BPH Treatment
√ Effective Lithotripsy
√ High Frequency Emission (up to 60 Hz)
√ Minimized Retropulsion
√ Advanced Pulse Modulation
√ Reduced Depth of Penetration (0.3 – 0.4 mm)
√ Soft Tissue Surgery
√ High Versatility
Large 12″ screen, rotation is a full 270° ⇐=⇒
Up to 65W, for fast HoLEP treatment and powerful cutting
Guided setting selection; save and reload your own presets
Intuitive GUI; great soft tissue surgery versatility from a wide range of emission settings
Virtual Basket ™ & Vapor Tunnel ™ modes, for advanced pulse modulation”
Wide range of fiber diameters / types available, for enhanced surgical versatility
Automatic aperture sensor for easy access to protected fiber port
MasterPULSE technology to fine-tune laser emission based on 7 pulse width steps
Up to 5J, enabling fragmentation of the hardest stones
Quiet performance
High Frequency Dusting of stones enchanded by up to 100Hz frequency for
Front (double) footswitch connection
Double Footswitch
The double footswitch enables immediate
access to multiple emission modes, with complete customization of MasterPULSE settings. No bothersome
interruptions are needed for settings readjustment.
* Mode #1 (e.g. cutting)
* Mode #2 (e.g. coagulation)
* Ready / Standby Switch
BPH
.HoLEP (Holmium Laser Enucleation of the Prostate) is a proven technique for the treatment of BPH (Benign Prostatic Hyperplasia), with high effectiveness, safety and durability. The large amount of literature demonstrates its advantages in terms of efficacy and safety with respect to traditional treatments available for BPH.
Recent studies and trials have validated the excellent outcomes achieved by this technique, with its success being reproduced in a diverse array of patients. HoLEP can be applied regardless of prostate size and in retreatment setting, with a low complication incidence and retreatment rate on long term follow-up.
Litho 100 offers wide choice regarding settings selection, with enhanced surgical experience granted by the double footswitch, the intuitive and large modulation of pulse width and the dedicated modes for the different treatment steps.
The different combinations of settings and multiple tools allow the maximum treatment versatility, so that the surgeon can easily reach the desired outcome. As alternative, the surgeon may use the side fiber to perform a HoLAP procedure for small prostatic adenomas.
√ Precise Cutting
√ User Preset Saving
√ Guided Selection of Settings
√ Double Footswitch
Starting 5 o’clock incision
12 o’clock incision
Lateral lobe enucleation
Quick switch from one emission mode to another (e.g. from cutting to coagulation emission)
Delicate Areas Mode
Dedicated Coagulation
Setting
User Friendly Software
FAST CUTTING
The limited depth of penetration, together with the fast tissue incision, results in precise cutting without affecting surrounding tissues
RELIABILTY
Clinical outcomes of HoLEP have been widely investigated, with any clinical studies demonstrating its safety and effectiveness also in the long run
SIZE INDEPENDENT
Effectiveness of HoLEP was proven also for large glands
EFFECTIVE HEMOSTASIS
The Holmium radiation is highly absorbed by water, allowing quick coagulation
HIGH POWER
Up to 105w output, for fast and quick incision
DOUBLE FOOTSWITCH
Quick switch between emission modes (eg. from cutting to coagulation emission)
Fragmentation
SHORT PULSE
(HIGH ENERGY)
HIGH PULSE ENERGY
Up to 5 J for wide pulse energy range
TREAT THE HARDEST STONES
Greater pulse energy allows breaking of harder stones
COLLECTION BASKET NEEDED
Retrieve stone pieces upon fragmentation
Dusting Effect
LONG PULSE
LIMITED RETROPULSION
Easy ablation with no need
to chase the stone
NO NEED FOR BASKET
The obtained fine dust obviates
the retrieval phase
LONG PULSE WIDTH
Up to 1100 μs;
smooth Long Pulse Dusting
EXTREME FREQUENCY
Up to 60 Hz;
enhanced speed in Dusting action
HIGH
FREQUENCY
Vapor Tunnel ™
Consisting of a Single Specific Long Pulse,
this emission mode allows limited retropulsion and fine stone ablation.
The Vapor Tunnel ™ is designed to use the minimum peak power in
accordance with selected output settings.
Bubble Dynamics of Vapor Tunnel ™ Time
Virtual Basket ™
The double pulse modulation used with the Virtual Basket ™ emission mode allows limited stone movements and fine lithotripsy.
Using Virtual Basket ™, a first pulse is used to generate the vapor bubble and a second pulse, emitted from the same fiber, propagates through the bubble to irradiate the target.
Bubble Dynamics of Virtual Basket ™
Advantages of Vapor Tunnel ™ and Virtual Basket ™
NO EXTRA COSTS
These modes do not need dedicated and more expensive fibers, bringing the mentioned advantages without extra expenses
GREAT STABILITY
Stone ablation and limited stone movement at the same time
EASIER TREATMENT
With a more stable target, lithotripsy treatment can proceed easily with fewer hassles
TIME SAVING
A limited stone movement limits the time-consuming fiber repositioning
Specific modulation of laser pulses generates longer bubbles able to extend further towards the target
This long bubble touching the target represents a direct connection between fiber tip and stone
MasterPULSE
CUTTING PRECISION
Adjust cutting fashion based
on your needs and the area of treatment
Example of HoLEP mode
General Benefits
Reducing retropulsion and modifying the tissue cutting get easier: instead of trying multiple different settings, start with your preferred ones and then adjust the MasterPULSE to tune the effect of laser emission based on your visual feedback.
Regulation of pulse width has never been so easy.
Example of Lithotripsy mode
REDUCED STONE INSTABILITY
Lower the stone instability
step by step, by progressively
increasing pulse width
EASE OF TREATMENT
Experience a more intuitive and different
way to adjust laser settings, simply based
on your visual feedback
FASTER TREATMENT TIME
Obtain the desired effect quickly, without losingtime with the standard adjustment of energy and frequency parameters
GREATER FLEXIBILITY
7 levels of pulse width offer a greater flexibility than the traditional 3 levels offered by the other holmium devices
Fibers
Litho 60 device can be operated
with a large range of fibers, depending
on the application, flexibility and
settings required.
STANDARD FIBERS
For general use in stone and soft tissue treatments
BALL TIP FIBERS
Strongly simplify the insertion in already bent scopes
SIDE FIBERS
Allows side ablation of
soft tissue
PERFORMANCE FIBERS
Designed to deliver even greater power with small standard fibers
FIBER RECOGNITION
Litho 60 automatically adjusts
emission settings based on the
connected fiber diameter
AVAILABLE DIAMETERS
200, 272, 365, 550, 600, 800 and 1000μm
REUSABILITY
All fibers are available both as disposable and reusable (except ball tip and side fibers)
CLEANING
Reusable fibers can be
sterilized by Sterrad ®
and steam sterilization
STERILIZATION TRAY
A dedicated tray for sterilization of fibers and tools
Applications
Litho 60 can be used to perform lithotripsy and incision, excision, resection, ablation, vaporization, coagulation
and hemostasis of soft tissue in various medical specialties, including:
Technical Specifications
Wavelength | 2.1 μm |
Average Power | up to 105 W |
Repetition rate | up to 80 Hz |
Energy per pulse | up to 5 J |
Pulse duration | 50-1100 μs |
Beam delivery | Wide range of flexible silica fibers |
Aiming beam | 532 nm (adjustable <5 mW) – Class 3R |
Fiber recognition | RFID System |
Activation | Double footswitch |
Electrical requirements | 230 Vac; 50/60 Hz; 6.2 kVA – 208 Vac; 50/60 Hz; 6.2 kVA |
Cooling | Internal chiller |
Operating temperature | 10°C – 30°C |
Laser Class | 4 (IEC/EN 60825-1:2014) |
Dimensions | 52 cm (W) x 120 cm (D) x 123 cm (H) (monitor closed) |
Weight | 200 kg |
global
medical technology
distribution
International Medical Lasers is the proud, exclusive US partner of Quanta System.
Together, we provide best-in-class surgical lasers to the American market.
Contact us below and let us know how we can provide your organization with these market-leading medical technologies.
FIND US
International Medical Lasers
– Exclusive US Distributor for
Quanta System S.p.A. –
Operations Center
18057 SW Teton Ave,
Tualatin, OR 97062
CONTACTS
Phone :
+ 1 (503) 643-7526
E-mail : info@imlasers.com
© Quanta System. All rights reserved. Legal Notice